A 0.6 V MOS-Only Voltage Reference for Biomedical Applications with 40 ppm/∘C Temperature Drift
- Submitting institution
-
Oxford Brookes University
- Unit of assessment
- 12 - Engineering
- Output identifier
- 185741281
- Type
- D - Journal article
- DOI
-
10.1142/S0218126618501281
- Title of journal
- Journal of Circuits, Systems and Computers
- Article number
- 1850128
- First page
- -
- Volume
- 27
- Issue
- 8
- ISSN
- 0218-1266
- Open access status
- Compliant
- Month of publication
- November
- Year of publication
- 2017
- URL
-
-
- Supplementary information
-
-
- Request cross-referral to
- -
- Output has been delayed by COVID-19
- No
- COVID-19 affected output statement
- -
- Forensic science
- No
- Criminology
- No
- Interdisciplinary
- No
- Number of additional authors
-
5
- Research group(s)
-
-
- Proposed double-weighted
- No
- Reserve for an output with double weighting
- No
- Additional information
- The work was original in that it presented a novel technique for generating a temperature independent voltage reference. The significance is that would have a major impact on the development of ultra-low power biomedical systems. Applications include wearable and implantable biomedical monitors where power consumption is a major consideration. These could include things like 24 hours insulin level monitoring, heart monitoring etc.